We followed these instructions to set up a dedicated external port for each Compute Module NIC as we have several physical networks to work with (lab and management).

image

The catch was after completing the settings on Switch 1 everything kept working but once Switch 2’s Save Settings button was clicked on packets stopped flowing in and out of the IMS switches.

We did not, however, figure out exactly what was going on until we ran through the setup process a number of times as it turned out that one of the mezzanine network adapters has a faulty port thus contributing to the confusion.

After running through the setup process a few times we were able to replicate the problem consistently.

A call into Intel Channel Support and about 45 minutes with Christian and we had the answer:

image

Disable Span Tree for the external ports.

  1. Click on Configure Ports
  2. Change the Spanning Tree setting for the VLAN dedicated external ports
  • image
  • Click Apply
  • Click on Switch 2
  • Repeat
  • Once we had the above two steps complete:

    image

    All four NICs showed green and our setup went live without a hitch.

    We have one Compute Module running as DC and two others as Windows Server 2012 Hyper-V nodes for a 2012 failover cluster.

    We then have two Intel Server System SR1695GPRX2AC 1U single socket servers tied to a Promise VTrak E610sD that are running Windows Server 2008 R2 SP1 set up as Hyper-V nodes for a 2008 R2 cluster.

    Now that we have this networking problem figured out we can move on to our work!

    Philip Elder
    MPECS Inc.
    Microsoft Small Business Specialists
    Co-Author: SBS 2008 Blueprint Book

    Chef de partie in the SMBKitchen
    Find out more at
    www.thirdtier.net/enterprise-solutions-for-small-business/

    Windows Live Writer

    Intel Modular Server – Setting up Untagged VLANs for Dedicated ...


    We followed these instructions to set up a dedicated external port for each Compute Module NIC as we have several physical networks to work with (lab and management).

    image

    The catch was after completing the settings on Switch 1 everything kept working but once Switch 2’s Save Settings button was clicked on packets stopped flowing in and out of the IMS switches.

    We did not, however, figure out exactly what was going on until we ran through the setup process a number of times as it turned out that one of the mezzanine network adapters has a faulty port thus contributing to the confusion.

    After running through the setup process a few times we were able to replicate the problem consistently.

    A call into Intel Channel Support and about 45 minutes with Christian and we had the answer:

    image

    Disable Span Tree for the external ports.

    1. Click on Configure Ports
    2. Change the Spanning Tree setting for the VLAN dedicated external ports
    • image
  • Click Apply
  • Click on Switch 2
  • Repeat
  • Once we had the above two steps complete:

    image

    All four NICs showed green and our setup went live without a hitch.

    We have one Compute Module running as DC and two others as Windows Server 2012 Hyper-V nodes for a 2012 failover cluster.

    We then have two Intel Server System SR1695GPRX2AC 1U single socket servers tied to a Promise VTrak E610sD that are running Windows Server 2008 R2 SP1 set up as Hyper-V nodes for a 2008 R2 cluster.

    Now that we have this networking problem figured out we can move on to our work!

    Philip Elder
    MPECS Inc.
    Microsoft Small Business Specialists
    Co-Author: SBS 2008 Blueprint Book

    Chef de partie in the SMBKitchen
    Find out more at
    www.thirdtier.net/enterprise-solutions-for-small-business/

    Windows Live Writer

    Intel Modular Server – Setting up Untagged VLANs for Dedicated ...



    Here is a good start for a lab environment:

    A set of DAS JBOD units can used with two small nodes and 2 SAS based HBAs per node to stand up a Storage Spaces cluster using the Server 2012 R2 bits. A couple of MicroServer Gen8 boxes would round out the Hyper-V side of it.

    On this blog there are a lot of configurations discussed that utilize intelligent direct attached storage.

    • Basic setup
      • Intel Server System SR1695GPRX2AC pair with Promise VTrak E610sD or E310sD
      • This category search on the blog has a number of really good posts including configuration examples based on the SR1695GPRX2AC (blog category link)
        • This server unit has been our go-to for base configurations as it is an excellent and flexible platform
    • Advanced setup
      • Intel Server System R2208GZ4GC pair with the Promise VTrak E610sD or E310sD
    • All-Out Setup
      • All of the above plus LSI SAS 6160 Switch pair and Intel Modular Server with 3 nodes.

    In the above setups the key is the intelligent storage providing mitigation services to the SAS HBAs and OS access to the central storage.

    With the 2012 R2 bits we are going to put together a redundant JBOD setup for a Storage Spaces cluster. This is the next direction we are delving into as we can put together a small SS cluster for a very reasonable cost.

    Today, we are working on the following (similar to David Ziembicki’s setup) setup for clustered Storage Spaces:

    • Basic
      • Intel Server System R1208JP4OC with pair of SAS HBAs (RS25GB008) (2 nodes)
        • 32GB of ECC per node to start
      • Intel Storage System JBOD2224S2D2 JBOD2224S2DP Intel JBOD units (2 units)
        • JBOD is dual expander and dual port backplane
        • Seagate Savvio SAS drives are dual port
      • 1m SAS Cables (4)
      • Windows Server 2012 R2 beta – Storage Spaces Cluster Setup
      • Intel Server System R2208GZ4GC pair for Hyper-V nodes (we have had these in our lab for a year or so now).
        • 64GB to 128GB of ECC
      • Windows Server 2012 R2 beta or RTM – Hyper-V Nodes
    • Advanced
      • Add a pair of 8-Port or 12-Port NETGEAR 10Gbit Ethernet switches
        • Ports on each NIC would be split between switches for redundancy
      • Add a pair of Dual-Port 10Gbit PCIe and/or I/O Module NICs to each node
        • 10Gbit Ethernet would SMBv3 Storage Spaces located VHDX
        • 10Gbit Ethernet would be for Live Migration Network
      • LSI SAS Switches (we have a pair of these in our lab setting)
      • Additional Intel JBOD units to test switches and scaling storage out

    Using David Ziembicki’s setup though one would be able to start at the base level and put together a similar configuration on a budget.

    An HP MicroServer Gen8 would make an excellent platform for testing as they are relatively inexpensive and have pretty close to the full Intel virtualization Acceleration feature set.

    Note that the Sans Digital MS28X listed in his blog post splits drives 0-3 and 4-7 between the two available external SAS connections. That means that there is no ability to use this storage unit without an LSI SAS 6160 Switch pair (Sans Digital MS28X Quick Installation Guide PDF)!

    However, the Sans Digital MS8X6 unit does support redundancy and therefore they could be used to test Storage Spaces clustering configurations (Sans Digital MS8X6 Quick Installation Guide PDF).

    Of course, for the added functionality there will be an extra cost involved, however one could drop the LSI SAS Switch for a set of these units for about the cost of the original MS28X plus SAS Switch!

    • Storage Spaces Cluster
      • Storage Spaces Node
        • Intel Xeon E3-1230
        • Intel Server Board S1200BTLSH
        • 16GB ECC
        • Intel Integrated RAID RMS2AF040
        • 120GB Intel 320 Series SSD (or small 10K SAS) RAID 1 pair for host OS
        • Quad-Port Intel Gigabit Server NIC PCIe
        • Intel certified chassis (whether Intel or other)
      • Storage
        • Sans Digital MS8X6
          • 300GB 15K 3.5" SAS drives can be found for a good deal today
      • Hyper-V Node
        • Intel Xeon E3-1230
        • Intel Server Board S1200BTLSH
        • 32GB ECC
        • Intel Integrated RAID RMS2AF040
        • 120GB Intel 320 Series SSD (or small 10K SAS) RAID 1 pair for host OS
        • Quad-Port Intel Gigabit Server NIC PCIe
        • Intel certified chassis (whether Intel or other)
      • OPTIONS
        • Add Intel RMM4 for full KVM over IP
        • Add Dual-Port 10Gbit Intel Ethernet for SMBv3 and Live Migration Networks
        • Add Intel Storage Systems JBOD2224S2DP at a later date for full SAS Dual Port Redundancy

    There are so many different ways to go about this.

    The main thing is to start small and work one’s way up to a full scale server grade lab as the jobs come in! That’s how we built our own lab systems up and how we built up the knowledgebase and experience!

    EDIT: Oops, Star Wars on the mind. Intel Storage Systems part number should be JBOD2224S2DP (I had JBOD2224S2D2 above!). :)

    Philip Elder
    MPECS Inc.
    Microsoft Small Business Specialists
    Co-Author: SBS 2008 Blueprint Book

    Chef de partie in the SMBKitchen
    Find out more at
    www.thirdtier.net/enterprise-solutions-for-small-business/

    Windows Live Writer

    A Storage Spaces and Hyper-V Cluster Lab Guide


    Here is a good start for a lab environment:

    A set of DAS JBOD units can used with two small nodes and 2 SAS based HBAs per node to stand up a Storage Spaces cluster using the Server 2012 R2 bits. A couple of MicroServer Gen8 boxes would round out the Hyper-V side of it.

    On this blog there are a lot of configurations discussed that utilize intelligent direct attached storage.

    • Basic setup
      • Intel Server System SR1695GPRX2AC pair with Promise VTrak E610sD or E310sD
      • This category search on the blog has a number of really good posts including configuration examples based on the SR1695GPRX2AC (blog category link)
        • This server unit has been our go-to for base configurations as it is an excellent and flexible platform
    • Advanced setup
      • Intel Server System R2208GZ4GC pair with the Promise VTrak E610sD or E310sD
    • All-Out Setup
      • All of the above plus LSI SAS 6160 Switch pair and Intel Modular Server with 3 nodes.

    In the above setups the key is the intelligent storage providing mitigation services to the SAS HBAs and OS access to the central storage.

    With the 2012 R2 bits we are going to put together a redundant JBOD setup for a Storage Spaces cluster. This is the next direction we are delving into as we can put together a small SS cluster for a very reasonable cost.

    Today, we are working on the following (similar to David Ziembicki’s setup) setup for clustered Storage Spaces:

    • Basic
      • Intel Server System R1208JP4OC with pair of SAS HBAs (RS25GB008) (2 nodes)
        • 32GB of ECC per node to start
      • Intel Storage System JBOD2224S2D2 JBOD2224S2DP Intel JBOD units (2 units)
        • JBOD is dual expander and dual port backplane
        • Seagate Savvio SAS drives are dual port
      • 1m SAS Cables (4)
      • Windows Server 2012 R2 beta – Storage Spaces Cluster Setup
      • Intel Server System R2208GZ4GC pair for Hyper-V nodes (we have had these in our lab for a year or so now).
        • 64GB to 128GB of ECC
      • Windows Server 2012 R2 beta or RTM – Hyper-V Nodes
    • Advanced
      • Add a pair of 8-Port or 12-Port NETGEAR 10Gbit Ethernet switches
        • Ports on each NIC would be split between switches for redundancy
      • Add a pair of Dual-Port 10Gbit PCIe and/or I/O Module NICs to each node
        • 10Gbit Ethernet would SMBv3 Storage Spaces located VHDX
        • 10Gbit Ethernet would be for Live Migration Network
      • LSI SAS Switches (we have a pair of these in our lab setting)
      • Additional Intel JBOD units to test switches and scaling storage out

    Using David Ziembicki’s setup though one would be able to start at the base level and put together a similar configuration on a budget.

    An HP MicroServer Gen8 would make an excellent platform for testing as they are relatively inexpensive and have pretty close to the full Intel virtualization Acceleration feature set.

    Note that the Sans Digital MS28X listed in his blog post splits drives 0-3 and 4-7 between the two available external SAS connections. That means that there is no ability to use this storage unit without an LSI SAS 6160 Switch pair (Sans Digital MS28X Quick Installation Guide PDF)!

    However, the Sans Digital MS8X6 unit does support redundancy and therefore they could be used to test Storage Spaces clustering configurations (Sans Digital MS8X6 Quick Installation Guide PDF).

    Of course, for the added functionality there will be an extra cost involved, however one could drop the LSI SAS Switch for a set of these units for about the cost of the original MS28X plus SAS Switch!

    • Storage Spaces Cluster
      • Storage Spaces Node
        • Intel Xeon E3-1230
        • Intel Server Board S1200BTLSH
        • 16GB ECC
        • Intel Integrated RAID RMS2AF040
        • 120GB Intel 320 Series SSD (or small 10K SAS) RAID 1 pair for host OS
        • Quad-Port Intel Gigabit Server NIC PCIe
        • Intel certified chassis (whether Intel or other)
      • Storage
        • Sans Digital MS8X6
          • 300GB 15K 3.5" SAS drives can be found for a good deal today
      • Hyper-V Node
        • Intel Xeon E3-1230
        • Intel Server Board S1200BTLSH
        • 32GB ECC
        • Intel Integrated RAID RMS2AF040
        • 120GB Intel 320 Series SSD (or small 10K SAS) RAID 1 pair for host OS
        • Quad-Port Intel Gigabit Server NIC PCIe
        • Intel certified chassis (whether Intel or other)
      • OPTIONS
        • Add Intel RMM4 for full KVM over IP
        • Add Dual-Port 10Gbit Intel Ethernet for SMBv3 and Live Migration Networks
        • Add Intel Storage Systems JBOD2224S2DP at a later date for full SAS Dual Port Redundancy

    There are so many different ways to go about this.

    The main thing is to start small and work one’s way up to a full scale server grade lab as the jobs come in! That’s how we built our own lab systems up and how we built up the knowledgebase and experience!

    EDIT: Oops, Star Wars on the mind. Intel Storage Systems part number should be JBOD2224S2DP (I had JBOD2224S2D2 above!). :)

    Philip Elder
    MPECS Inc.
    Microsoft Small Business Specialists
    Co-Author: SBS 2008 Blueprint Book

    Chef de partie in the SMBKitchen
    Find out more at
    www.thirdtier.net/enterprise-solutions-for-small-business/

    Windows Live Writer

    A Storage Spaces and Hyper-V Cluster Lab Guide


    I'm very excited to announce that my Hyper-V Configuration Guide has been released to the SMBKitchen Project's knowledgebase! I walk through a number of critical areas in this guide relative to deploying a properly sized Hyper-V virtualization solutio...

    SMBKitchen: My Hyper-V Configuration Guide Is Released!



    I'm very excited to announce that my Hyper-V Configuration Guide has been released to the SMBKitchen Project's knowledgebase! I walk through a number of critical areas in this guide relative to deploying a properly sized Hyper-V virtualization solutio...

    SMBKitchen: My Hyper-V Configuration Guide Is Released!



    We use the Intel Server Configurator Tool _a lot_ for our on-premises Intel Server Systems configurations.

    So, we were a little more than surprised to see the following this morning:

    image

    We clicked the “Not Registered” link as our Intel Reseller username and password did not work and finally ended up here:

    image

    Okay, so registration is required. What could this mean? Well, since the tool has been open to the public for many years now it is hard to say at this point.

    But, one thing is pretty clear: Intel wants to know a bit more about the folks using the tool.

    EDIT: Meh ... hit SEND too quickly. :S

    For those of us that have used this tool for a long time we will get a pleasant surprise once we click into the wizard:

    image

    Instead of a hard-to-read text based description of each product line we can finally see a nice grid with pictures of each product. This is how the Configurator used to look before Silverlight took over.

    This is definitely a step in the right direction! :D

    Philip Elder
    MPECS Inc.
    Microsoft Small Business Specialists
    Co-Author: SBS 2008 Blueprint Book

    Chef de partie in the SMBKitchen
    Find out more at
    www.thirdtier.net/enterprise-solutions-for-small-business/

    Windows Live Writer

    Intel Server Configurator Tool – Registration Required